Home
PDI
More
on PDI

Control Systems
Rental
Equipment
Rental
Winches
Surplus
Equipment
|
|
|
|
| Power Dynamics LLC maintains the following winches for rent.
|
|
Main Winch |
|
Specifications |
|
|
|
Drum
Barrel Dia. |
in. |
25.00 |
| |
Drum
Flange Dia. |
in. |
51.13 |
| |
Drum
Between Flanges |
in. |
40.00 |
| |
Cable
Size |
in. |
1.375 |
| |
Cable
Storage |
ft. |
1,785 |
| |
Qty of
Layers |
|
7 |
| |
Drum
Torque |
lb. in. |
1,023,705 |
| |
Drum
Speed |
rpm |
22.5 |
| |
Drum
Power |
hp |
365.46 |
| |
Primary
Reduction |
|
4 |
| |
Secondary
Reduction |
|
5 |
| |
Final
Reduction |
|
4 |
| |
Actual
Total Ratio |
|
80.00 |
| |
Req'd
Motor Torque |
lb. in. @ .965 |
14.240 |
| |
Req'd
Motor Speed |
rpm |
1,800 |
| |
Motor
Displacement |
cc |
355 |
| |
Motor
Displacement |
cu. in. |
21.66 |
| |
Hyd
Pressure-Run |
psi @ .93 |
4,442 |
| |
Hyd
Pressure-Start |
psi @ .87 |
4,748 |
| |
Hyd Flow |
gpm @ .97 |
174 |
|
|
Winch |
|
Specifications |
|
|
|
Drum
Barrel Dia. |
in. |
27.00 |
| |
Drum
Flange Dia. |
in. |
41.63 |
| |
Drum
Between Flanges |
in. |
40.00 |
| |
Cable
Size |
in. |
1.125 |
| |
Cable
Storage |
ft. |
1,131 |
| |
Qty of
Layers |
|
4 |
| |
Drum
Torque |
lb. in. |
490,950 |
| |
Drum
Speed |
rpm |
48.2 |
| |
Drum
Power |
hp |
375.47 |
| |
Primary
Reduction |
|
7.5 |
| |
Secondary
Reduction |
|
5 |
| |
Final
Reduction |
|
1 |
| |
Actual
Total Ratio |
|
37.50 |
| |
Req'd
Motor Torque |
lb. in. @ .965 |
14,569 |
| |
Req'd
Motor Speed |
rpm |
1,808 |
| |
Motor
Displacement |
cc |
355 |
| |
Motor
Displacement |
cu. in. |
21.66 |
| |
Hyd
Pressure-Run |
psi @ .93 |
4,544 |
| |
Hyd
Pressure-Start |
psi @ .87 |
4858 |
| |
Hyd Flow |
gpm @ .97 |
175 |
|
|
Luffing Winch |
|
Specifications |
|
|
|
Drum
Barrel Dia. |
in. |
18.00 |
| |
Drum
Flange Dia. |
in. |
31.00 |
| |
Drum
Between Flanges |
in. |
24.00 |
| |
Cable
Size |
in. |
1.000 |
| |
Cable
Storage |
ft. |
470 |
| |
Qty of
Layers |
|
4 |
| |
Drum
Torque |
lb. in. |
317,525 |
| |
Drum
Speed |
rpm |
34 |
| |
Drum
Power |
hp |
171.29 |
| |
Primary
Reduction |
|
7.5 |
| |
Secondary
Reduction |
|
5 |
| |
Final
Reduction |
|
1 |
| |
Actual
Total Ratio |
|
37.50 |
| |
Req'd
Motor Torque |
lb. in. @ .965 |
9,422 |
| |
Req'd
Motor Speed |
rpm |
1,275 |
| |
Motor
Displacement |
cc |
250 |
| |
Motor
Displacement |
cu. in. |
15.25 |
| |
Hyd
Pressure-Run |
psi @ .93 |
4,174 |
| |
Hyd
Pressure-Start |
psi @ .87 |
4,461 |
| |
Hyd Flow |
gpm @ .97 |
87 |
|
Back to
top
Call Power Dynamics LLC for all
your rental needs!
|
|
- Power Dynamics LLC
- MSAAP, Building 9166
- Stennis Space Center, MS 39529
- Phone: (228) 689-8560
- Fax: (228) 689-8570
- E-mail:
mshockley@pdi-entech.com
|
Back to top 2002 [Power Dynamics,
Inc.-Entech Systems]. All rights reserved.
Revised:
03/30/06 |